Hazard Warning Switch Inspection
1. Disconnect the negative battery cable..
2. Remove the decoration panel..
3. Verify that the continuity between the hazard warning switch terminals is
as indicated in the table.
If the continuity is as indicated in the table, go to the next step.
If not as indicated i ...
Sas Control Module Removal/Installation [Standard Deployment Control System]
WARNING:
Handling the SAS control module or air bag module improperly can accidentally
deploy the air bag modules and pre-tensioner seat belts, which may seriously
injure you. Read the air bag system service warnings and cautions before handling
the air bag module..
If the c ...
Oil Control Valve (OCV) Inspection
Coil Resistance Inspection
1. Disconnect the negative battery cable..
2. Remove the plug hole plate..
3. Disconnect the OCV connector.
4. Measure the resistance between terminals A and B using an ohmmeter.
OCV coil resistance
6.9—7.5 ohms [20°C {68°F}]