Resistance Inspection
1. Remove the KS..
2. Measure the resistance between KS terminals A and B.

If not as specified, replace the KS..
504—616 kilohms [10—30 °C {50—86 °F}]
Intake Air Temperature (Iat) Sensor
Knock Sensor (Ks) Removal/InstallationTcs Off Switch Inspection
1. Remove the TCS OFF switch..
2. Verify that the resistance between the TCS OFF switch terminals B and C is
as indicated in the table.
If not as indicated in the table, replace the TCS OFF switch.
TCS OFF switch specification
Terminal
Test con ...
Evaporator
Purpose
The evaporator cools the passing air.
Function
The evaporator vaporizes the atomized refrigerant flowing internally, and
the air passing through the evaporator is cooled by the release of latent heat.
The moisture in the air is condensed at this time and dehumidifie ...
Generator [Skyactiv G 2.0]
Purpose, Function
The generator operates by obtaining drive force from the engine via the drive
belt and generates the required electricity for electronic devices.
Construction
The generator is installed on the engine left front side.
Output control is perfor ...