Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Engine Coolant Temperature (ECT) Sensor

Mazda CX-5 Service & Repair Manual / Engine / Cooling / Engine Coolant Temperature (ECT) Sensor

Purpose/Function

Construction

ECT sensor No.1

ECT sensor No.2

Operation

ECT sensor characteristic


Fail-safe

ECT sensor No.1


DTC No.

Fail-safe function

P0117:00

  • Fixes the water temperature for the engine control at 40 °C {104 °F}, and for the idle air control at 80 °C {176 °F}.

  • Operates the cooling fan (high speed rotation).

  • Inhibits the fuel cut control during shift change.

P0118:00

  • Fixes the water temperature for the engine control at 40 °C {104 °F}, and for the idle air control at 80 °C {176 °F}.

  • Operates the cooling fan (high speed rotation).

  • Inhibits the fuel cut control during shift change.


ECT sensor No.2

Engine Coolant Temperature (ECT) Sensor Removal/Installation
WARNING: When the engine is hot, it can badly burn. Turn off the engine and wait until it is cool before removing the ECT sensor. ECT Sensor No.1 1. Disconnect the negative battery c ...

Fan Switch Inspection [Manual Air Conditioner]
1. Disconnect the negative battery cable.. 2. Remove the following parts: a. Shift lever knob (MTX). b. Glove compartment. c. Front console box. d. Shift panel. e. Upper panel. f. Rear c ...

Other materials:

Turn Signal/Hazard Warning Indicator Lights
Purpose Notifies the driver that a turn light, the hazard warning lights are flashing. Function Flashes according to the turn switch and hazard warning switch operations. Construction Displayed in the instrument cluster. Operation Turn system 1. When th ...

Starting the Engine
WARNING Radio waves from the key may affect medical devices such as pacemakers: Before using the key near people who use medical devices, ask the medical device manufacturer or your physician if radio waves from the key will affect the device. NOTE • The key must be carried because the ke ...

Evaporator Temperature Sensor Inspection [Manual Air Conditioner]
NOTE: Inspect the evaporator temperature sensor when it is installed to the A/C unit. 1. Set the fan speed at MAX HI. 2. Set the temperature control at MAX COLD. 3. Set the RECIRCULATE mode. 4. Turn the A/C switch off. 5. Close all doors and windows. 6. Wait for 5 min. 7 ...

© 2016-2026 Copyright www.mcx5.org