Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Thermostat Removal/Installation

Mazda CX-5 Service & Repair Manual / Engine / Cooling / Thermostat Removal/Installation

WARNING:

1. Disconnect the negative battery cable..

2. Drain the engine coolant..

3. Remove the plug hole plate..

4. Remove the air cleaner, air hose and fresh air duct component..

5. Remove the battery, battery tray and PCM component..

6. Remove in the order indicated in the table.

7. Install in the reverse order of removal.

8. Refill the engine coolant..

9. Inspect for engine coolant leakage..



1

Lower radiator hose (Thermostat cover side)

2

Thermostat cover

(See Thermostat Cover Removal Note.)

3

Thermostat

(See Thermostat Installation Note.)


Thermostat Cover Removal Note

1. Place rags on the transaxle case around the area under the thermostat cover.

2. Slightly loosen the three

thermostat cover bolts and use the rags to absorb the draining engine coolant.

CAUTION:

3. After the engine coolant stops draining, remove the thermostat cover.

Thermostat Installation Note

1. Install the thermostat with the jiggle pin aligned with the notch of the water outlet.


Thermostat Inspection
1. Remove the thermostat.. 2. Visually check that the thermostat valve is closed. 3. Place the thermostat in water. WARNING: During inspection, the thermostat and water are extremely hot ...

Thermostat
Purpose, Function When the engine coolant temperature is low, the thermostat blocks the engine coolant passage between the radiator and engine. As a result, because engine coolant cycles ...

Other materials:

Oil Seal (Control Valve Body) Replacement [Fw6 A EL, Fw6 Ax EL]
1. Disconnect the negative battery cable.. 2. Remove the air cleaner component.. 3. Disconnect the control valve body connector. CAUTION: Make sure that your hand does not touch the terminal as the connector terminal could be damaged. Water or foreign objects entering th ...

Torque Box Removal [Panel Replacement]
Symbol Mark Removal Procedure 1. Drill the 19 locations indicated by (A) shown in the figure. NOTE: When drilling the 19 locations indicated by (A) shown in the figure, do not drill a hole all the way through or there could be a problem when installing the new part. 2 ...

Start Stop Unit Inspection
1. Remove the following parts: a. Column cover. 2. Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference). If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) a ...