Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Negative Battery Cable Disconnection/Connection [Skyactiv G 2.0]

Mazda CX-5 Service & Repair Manual / Electrical / Battery / Negative Battery Cable Disconnection/Connection [Skyactiv G 2.0]

WARNING:

Required procedure after negative battery cable disconnection/connection


System name

Conditions after disconnecting the negative battery cable

Required procedure

Reference

Before disconnecting negative battery cable

After connecting negative battery cable

Power window system

Reset to initial setting and auto-function is disabled.

?

Perform the power window system initial setting.

(See POWER WINDOW SYSTEM INITIALIZATION PROCEDURE.)

Clock and audio

Clock display and audio system memory are reset.

Verify the setting content.

Set the verified content before disconnecting negative battery cable.

?

Tire pressure monitoring system (TPMS)

The tire pressure monitoring system detection accuracy decreases.

?

Perform the tire pressure monitoring system initialization.

(See TIRE PRESSURE MONITORING SYSTEM INITIALIZATION PROCEDURE.)


Negative Battery Cable Disconnection

1. Switch the ignition off.

2. Disconnect the negative battery cable.

Negative Battery Cable Connection

CAUTION:

1. Perform services required after connecting the negative battery cable..

Battery [Skyactiv G 2.0]
Purpose, Function The battery stores electricity generated by the generator. In addition, it supplies power to electronic devices if necessary. Construction The battery is insta ...

Remote Transmitter Battery Voltage Inspection
NOTE: Because the remote transmitter battery power cannot be determined using the battery itself, determine by the remote transmitter battery low warning operation conditions. Oper ...

Other materials:

Refrigerant Pressure Sensor [Full Auto Air Conditioner]
Purpose The refrigerant pressure sensor detects the refrigerant pressure in the refrigerant cycle. Function The refrigerant pressure sensor converts the detected refrigerant pressure to an electric signal and sends it to the PCM. Construction The refriger ...

Auto Leveling Sensor Inspection
1. Disconnect the negative battery cable.. 2. Remove the auto leveling sensor.. 3. Prepare three dry cell batteries (1.5 V). 4. Connect the three dry cell batteries in a series. 5. Connect the positive pole of the dry cell battery to auto leveling sensor terminal C, and the negative po ...

Ion Sensor Inspection
DTC Inspection 1. Connect the M-MDS to the DLC?2. 2. Perform the DTC inspection using the M-MDS.. If any DTC related to the ignition coil/ion sensor is present, repair the malfunctioning location according to the applicable DTC troubleshooting.. Visual Inspection NOTE: B ...