U.S.A. And CANADA
Purpose, function
Seals the atmosphere side of the charcoal canister during EVAP leak check monitoring.
Construction
Included in the charcoal canister.

The CV solenoid valve is consists of O-rings.

Operation
According to the control signal from the PCM, the coil is energized and the plunger opens/closes the CV solenoid valve.

Fail-safe
Function not equipped.
Canister Vent (Cv) Solenoid Valve Removal/Installation
Catalytic ConverterNon Return Valve Inspection
WARNING:
Fuel is very flammable liquid. If fuel spills or leaks from the pressurized
fuel system, it will cause serious injury or death and facility breakage. Fuel
can also irritate skin and eyes. To prevent this, always complete the “Fuel
Line Safety Procedure”, while referring ...
Brake Pedal Inspection
Pedal Height Inspection
1. Measure the distance from the center of the upper surface of the pedal pad
to the insulator and verify that it is as specified.
If not within the specification, inspect the following items and repair or
replace the applicable part if there is any malfunct ...
Heated Oxygen Sensor (HO2 S) Heater Control [Skyactiv G 2.0]
Outline
Based on the control of the HO2S heater, a stabilized oxygen concentration
is detected even at low exhaust temperatures, and feedback control of fuel injection
even at cold engine start is made possible for improved cold temperature exhaust
emission performance.
Both ...