Symbol Mark

Removal Procedure
1. Drill the 11 location shown in the figure.

2. Remove the corner plate.
Corner Plate Installation [Panel Replacement]
Dumping Sheet Replacement [Water Proof And Rust Preventive]PCM Inspection
Without Using the M-MDS
NOTE:
Because the PCM uses a waterproof connector, the inspection for the voltage/wave
pattern cannot be performed. The following values are for reference.
Terminal voltage table (Reference)
Terminal
Signal
C ...
Units
Electric current
A (ampere)
Electric power
W (watt)
Electric resistance
ohm
Electric voltage
V (volt)
Length
mm (millimeter)
in (inch)
...
Purge Solenoid Valve
Purpose, Function
Introduces evaporative gas absorbed by the charcoal canister to the intake
manifold.
The purge solenoid valve opens according to the control signal from the PCM.
Construction
The purge solenoid valve is installed in the engine compartment.
...