Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Battery Inspection [Skyactiv G 2.0]

Mazda CX-5 Service & Repair Manual / Electrical / Battery / Battery Inspection [Skyactiv G 2.0]

WARNING:

  1. Since battery acid is toxic, be careful when handling the battery.

  2. Since battery acid is highly corrosive, be careful not to allow it to contact clothing or the vehicle.

  3. In case battery acid contacts skin, eyes, or clothing, flush it immediately with running water. If the acid gets in the eyes, flush with water for more than 15 min and get prompt medical attention.

Using GR8-1291:

(See GR8-1291 INSTANT TRAINING MODULE (VIDEO).)

1. Remove the battery filler caps and check the water level. If necessary, add water to the appropriate level. Reinstall the caps.

2. Attach the small red clamp to the positive battery terminal and the small black clamp to the negative terminal.

3. Select the Battery Test icon in the Main Menu, then press the NEXT key.

4. Test the battery by following the on-screen instructions to enter the appropriate information. Refer to the Mazda GR8-1291 Instruction Manual for more information.

5. After the test, the Control Module displays a battery decision with an analysis in a series of screens. The analysis includes the battery state of health (SOH) and state of charge (SOC). Before the Battery Test results are displayed, use the keypad on the Control Module to enter the last 5 digits of the vehicle's VIN and press NEXT to continue.

6. The Mazda GR8-1291 will print out the test results and display one of the eight possible results listed below. Review the results and follow the Action Step for the displayed result.


Battery Tester Display

Action Step

GOOD BATTERY

Return the battery to service.

GOOD - RECHARGE

Fully charge the battery and return it to service.

CHARGE & RETEST

Fully charge the battery and retest. Failure to fully charge the battery before retesting may cause false readings. If CHARGE & RETEST appears again after you fully charge the battery, replace the battery.

REPLACE BATTERY

A REPLACE BATTERY result may also mean a poor connection between the battery and the vehicle. If you tested the battery using the System test, disconnect the battery cables and retest using the Battery Test before replacing it.

BAD CELL - REPLACE

Replace the battery.

WARNING:

  • Do not charge the battery. Charging a battery with one or more bad cells could cause an explosion and serious harm to the user.

SIDE POST TEST

Test data was inconclusive using the side post. Retest using side post adapters.

JUMP START POST

Data was inconclusive using the jump start post. Retest at the battery terminals.

24 VOLT BATTERY

24-volt battery detected. You are attempting to test both in-vehicle batteries in a 24-volt system. Disconnect the batteries and test them individually.


Using Electrolyte Specific Gravity Method:

1. Remove the battery filler caps and check the water level.

2. Measure the electrolyte specific gravity using a hydrometer.

Using Battery Voltage Method:

1. Inspect the battery as follows after removing the battery filler caps, checking the water level, and adding water to the appropriate level if needed:

Step

Inspection

Results

Action

1

Measure the battery positive voltage.

12.4 V or more

Go to Step 3.

Less than 12.4 V

Go to the next step.

2

Quick charge for 30 min

and recheck voltage.

12.4 V or more

Go to the next step.

Less than 12.4 V

Replace the battery.

3

Using the battery load tester, apply load current (see battery load test current) and record battery voltage after 15 s

. Is voltage more than the specification?

Yes

Normal

No

Replace the battery.


Standard specification

Battery temp. (°C {°F})

Minimum voltage (V)

4 {39}

9.3

10 {50}

9.4

16 {61}

9.5

21 {70}

9.6


Parasitic Draw Inspection

(See GR8-1291 PARASITIC DRAW TESTING INSTANT TRAINING (VIDEO).)

1. Verify that the ignition is switched off (lock) and all doors, the hood and the trunk/liftgate are closed.

2. If using a series-type ammeter, continue to Step 3. If using the GR8-1291 Battery Maintenance Station with the inductive amp clamp, skip to Step 6.

3. Disconnect the negative battery cable..

CAUTION:

4. Connect the meter between the negative battery terminal and negative battery cable. Proceed to Step 10.

5. Select the DMM icon from the main menu.

6. Select the DC Ammeter.

7. Select the 70 AMP MAX range. (measuring milliamps)

8. Connect the amp clamp to the negative battery cable.

9. Monitor the current draw.

NOTE:

10. Leave the vehicle electrical system undisturbed for 10 min or more, but less than 2.5 hours

, and then measure the parasitic draw.

NOTE:

Battery
...

Battery Recharging [Skyactiv G 2.0]
Using GR8-1291: (See GR8-1291 INSTANT TRAINING MODULE (VIDEO).) WARNING: Keep all flames away from the battery, otherwise evaporated gas from the battery fluid may catch fire and cause se ...

Other materials:

Tire Pressure Monitoring System (TPMS)
Purpose, Outline The tire pressure monitoring system monitors the tire pressure of all 4 tires. If the tire pressure of 1 tire or more becomes excessively low, the driver is notified. A tire pressure monitoring system has been adopted which indirectly inspects the tire pres ...

Front Sash Molding Removal
WARNING: Using a utility knife with bare hands can cause injury. Always wear gloves when using a utility knife. 1. Using a utility knife, carefully remove the double-sided adhesive tape in the locations shown below. CAUTION: When removing the double-sided adhesive tape, ...

Bsm Indicator Light Flashes While Not Under Bsm Indicator Light Flashing Conditions (No Combination Switch Operation (Turn Signal Switch)) [Blind Spot Monitoring (Bsm)]
Description BSM indicator light flashes while not under BSM indicator light-flashing conditions (no combination switch operation (turn signal switch) The BSM indicator light flashes despite not satisfying the BSM indicator light flashing ...