Outline
The PCM controls energization to the starter relay according to an immobilizer system request to improve security.
While not in P or N position, the starter relay energization by the ignition key is inhibited. (ATX)
While not in neutral, the starter relay energization by the push button start is inhibited. (MTX)
Block Diagram

Operation
The PCM establishes a ground to the starter circuit. Therefore when the ignition is switched to START, the starter relay is energized and the starter motor rotates. As a result, the engine starts normally.
The PCM does not establish a ground to the starter circuit. Therefore, even if the ignition switch is turned to the start position, the starter motor does not rotate because the starter relay does not energize, and the engine does not start.

The PCM turns the starter relay off with the engine speed at the set value or more (value from engine coolant temperature fluctuates).
Refrigerant Charging
Starter Disassembly/Assembly [Skyactiv G 2.0]Drive Belt Inspection
Generator Drive Belt
NOTE:
The generator drive belt deflection/tension inspection is not necessary with
the adoption of the drive belt auto tensioner.
1. Verify that the indicator part of the cast hexagon on the drive belt auto
tensioner is within the normal range.
If ...
Check Valve
Except U.S.A. And CANADA
Purpose, function
The check valve maintain the pressure in the fuel tank at constant pressure.
Construction
The check valve is installed to the side of the charcoal canister.
Mainly consists of valve, umbrella, and spring.
O ...
Differential Oil Replacement
1. Place the vehicle on level ground.
2. Remove the filler plug.
3. Remove the drain plug and drain the differential oil into a container.
4. Install a new washer and the drain plug, and tighten.
Tightening torque
40—53 N·m {4.1—5.4 kgf·m, 30—39 ft·lbf}
5. Add the ...