Outline
The PCM controls energization to the starter relay according to an immobilizer system request to improve security.
While not in P or N position, the starter relay energization by the ignition key is inhibited. (ATX)
While not in neutral, the starter relay energization by the push button start is inhibited. (MTX)
Block Diagram

Operation
The PCM establishes a ground to the starter circuit. Therefore when the ignition is switched to START, the starter relay is energized and the starter motor rotates. As a result, the engine starts normally.
The PCM does not establish a ground to the starter circuit. Therefore, even if the ignition switch is turned to the start position, the starter motor does not rotate because the starter relay does not energize, and the engine does not start.

The PCM turns the starter relay off with the engine speed at the set value or more (value from engine coolant temperature fluctuates).
Refrigerant Charging
Starter Disassembly/Assembly [Skyactiv G 2.0]Underbody Dimensions [Dimensions]
NOTE:
The following figure is a bottom view.
Point symbol
Designation
Hole diameter or bolt or nut size mm {in}
A
Front crossmember installation hole
?24 {0.94}
B
Fro ...
Brake Hose (Front) Removal/Installation
1. Remove in the order indicated in the table.
2. Install in the reverse order of removal.
3. After installation, add brake fluid, bleed the air, and inspect for fluid
leakage..
1
Brake pipe
2
Clip
3
Bolt
...
Check Valve Inspection
Except U.S.A. And CANADA
1. Remove the check valve..
2. Verify that there is no airflow when positive pressure is applied to port
A.
If there is airflow, replace the check valve..
3. Verify that there is no airflow when negative pressure is applied to port
A.
If ther ...