Purpose, Function
Absorbs evaporative gas flowing from the fuel tank to prevent release of the gas into the atmosphere.
Construction
The charcoal canister is installed near the fuel tank.
U.S.A. and CANADA

Except U.S.A. and CANADA

The charcoal canister has activated charcoal to absorb evaporative gas.
Operation
When the purge solenoid valve is open, evaporative gas, which is absorbed by the activated charcoal, is released by the intake manifold vacuum and the gas flows to the intake manifold.
U.S.A. and CANADA

Except U.S.A. and CANADA

Charcoal Canister Removal/Installation
Check Valve InspectionD Pillar Reinforcement (Lower) Installation [Panel Replacement]
Symbol Mark
Installation Procedure
1. When installing new parts, measure and adjust the body as necessary to conform
with standard dimensions.
2. Drill holes for the plug welding before installing the new parts.
3. After temporarily installing new parts, make sure the related parts fit p ...
Magnetic Clutch Disassembly/Assembly [Full Auto Air Conditioner]
1. Disassemble in the order indicated in the table.
1
Bolt
(See Bolt Removal/Installation Note.)
2
Pressure plate
3
Shim
(See Shim Installation Note.)
4
Snap ring
(See Snap Ring ...
Magnetic Clutch Adjustment [Full Auto Air Conditioner]
1. Measure the clearance around the entire circumference between the pressure
plate and A/C compressor pulley using a thickness gauge.
2. Verify the clearance.
If not within the specification, remove the pressure plate and adjust the
clearance by changing the shim (0.2 mm {0.008 i ...