U.S.A. And CANADA
Purpose, function
Seals the atmosphere side of the charcoal canister during EVAP leak check monitoring.
Construction
Included in the charcoal canister.

The CV solenoid valve is consists of O-rings.

Operation
According to the control signal from the PCM, the coil is energized and the plunger opens/closes the CV solenoid valve.

Fail-safe
Function not equipped.
Canister Vent (Cv) Solenoid Valve Removal/Installation
Catalytic ConverterShift Lever [C66 M R]
Purpose, Function
The shift lever operates the MTX via the control cable.
Construction
Shift lever
The shift lever is designed to prevent improper shifting to 1st gear and
reverse.
Operation
1 GR shifting
A guide plate, attached to the shift lever assembly, ...
Front Door Latch Switch Inspection
1. Perform the front door glass preparation..
2. Disconnect the negative battery cable..
3. Remove the following parts:
a. Inner garnish.
b. Front door trim.
c. Front door glass.
d. Front door module panel.
e. Front door key cylinder.
f. Front door latch and lock actuator.
4. Verif ...
Start Stop Unit Configuration (Using Read/Write Function)
NOTE:
When performing configuration, it is necessary to read the vehicle specification
information from the start stop unit before replacing it. Connect the M-MDS
to the vehicle and perform vehicle identification before removing the start
stop unit. The vehicle specification informa ...