1. Measure the temperature around the ambient temperature sensor and measure the resistance between the ambient temperature sensor terminal.
If the characteristics of the ambient temperature sensor are not as shown in the graph, replace the ambient temperature sensor.
Spark Plug [Skyactiv G 2.0]
Purpose, Function
The spark plug generates spark, ignition of the air-fuel mixture occurs,
and combustion of the air-fuel mixture is triggered.
Construction
The spark plug is installed to the cylinder head.
Iridium on the center electrode and platinum on the ...
Cabin Side Frame Straight Line Dimensions [Dimensions]
Point symbol
Designation
Hole diameter or bolt or nut size mm {in}
A
Front side frame outer datum hole
?12 {0.47}
B
Front fender panel installation hole
?10 {0.39}
...
Condenser Inspection
1. Inspect the condenser for cracks, damage, and oil leakage.
If there is any malfunction, replace the condenser.
2. Visually inspect for bent fins for clogging of foreign material.
If any fins are clogged, remove the foreign material.
3. Visually inspect for bent fins.
...