Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Purge Solenoid Valve Inspection

Mazda CX-5 Service & Repair Manual / Engine / Emissions / Purge Solenoid Valve Inspection

Airflow Inspection

1. Disconnect the negative battery cable..

2. Remove the purge solenoid valve..

3. Inspect airflow between the ports under the following conditions.



Measured condition

Continuity between ports A—B

When voltage is not applied between terminals A and B

No airflow

When voltage is applied between terminals A and B

Airflow detected


Positive Crankcase Ventilation (PCV) Valve
Purpose, Function Prevents release of blow-by gas (unburnt gas) into the atmosphere. The PCV valve is open/closed by the intake manifold vacuum. Construction The PCV valve ...

Purge Solenoid Valve Removal/Installation
1. Disconnect the negative battery cable.. 2. Remove the plug hole plate.. 3. Remove the air cleaner and air hose as a single unit.. 4. Disconnect the high pressure fuel pump connector. 5. Dis ...

Other materials:

Washer Fluid
InspectingWasher Fluid Level WARNING Use only windshield washer fluid or plain water in the reservoir: Using radiator antifreeze as washer fluid is dangerous. If sprayed on the windshield, it will dirty the windshield, affect your visibility, and could result in an accident. Using Washer Fluid ...

Condenser Removal/Installation
1. Disconnect the negative battery cable.. 2. Remove the following parts: a. Trunk board. b. Trunk end trim (LH). c. Rear scuff plate (LH). d. Trunk side trim (LH). e. D-pillar trim (LH). 3. Disconnect the connector. 4. Remove the bolts. 5. Remove the condenser. 6. Install in ...

Electric Variable Valve Timing Actuator Inspection
WARNING: A hot engine can cause severe burns. Turn off the engine and wait until it is cool before servicing. CAUTION: Do not disassemble the electric variable valve timing actuator because it is a precision unit. 1. Disconnect the negative battery cable.. 2. Remo ...

© 2016-2025 Copyright www.mcx5.org