Purpose
Fuses used by each system are grouped and housed together for smooth inspection and replacement servicing.
Function
Fuses used by each system are grouped and housed together.
Construction
Installed inside the front side trim (LH).

Operation
Fuse operation
1. If electric current to each fuse is the specified value or more, the fuse melts due to heat generation.
2. Interrupts electric current flow downstream of the fuse.
Fail-safe
Function not equipped.
Fuel Injector Relay [Skyactiv G 2.0]
Main FusePressure Control Valve Inspection [Skyactiv G 2.0]
1. Remove the pressure control valve assembly..
CAUTION:
Do not apply a pressure 36 kPa {0.37 kgf/cm2, 5.2 psi} or more. Doing so
will damage the pressure control valve and evaporative hose.
2. Apply a pressure of 36 kPa {0.37 kgf/cm2, 5.2 psi} to port A.
3. Verify that ther ...
Resistor Inspection [Manual Air Conditioner]
1. Verify that the resistance between the resistor terminals is as shown in the
table.
If there is any malfunction, replace the resistor.
Terminal
Resistance (ohm)
A—D
0.35—0.41
A—B
0. ...
Front Fog Light Removal/Installation
1. Disconnect the negative battery cable..
2. Remove the screws and bolt.
3. Pull up the front under cover No.1 and remove the mudguard screw shown in
the figure.
4. Disconnect the connector.
5. While pressing the clip tab in the direction of the arrow (1) shown in the
figure ...