1. Measure the temperature around the ambient temperature sensor and measure the resistance between the ambient temperature sensor terminal.

If the characteristics of the ambient temperature sensor are not as shown in the graph, replace the ambient temperature sensor.
Ambient Temperature Sensor Inspection [Manual Air Conditioner]Check Valve Inspection
Except U.S.A. And CANADA
1. Remove the check valve..
2. Verify that there is no airflow when positive pressure is applied to port
A.
If there is airflow, replace the check valve..
3. Verify that there is no airflow when negative pressure is applied to port
A.
If ther ...
C Pillar Trim Removal/Installation
1. Disconnect the negative battery cable..
2. Remove the following parts:
a. Trunk board.
b. Trunk end trim.
c. Rear scuff plate.
d. Trunk side trim.
e. D-pillar trim.
3. Partially peel back the seaming welt.
4. Remove the fastener A.
5. Take the shaded area shown in the figure ...
Room Light Control System
Outline
The room light control system changes the illumination condition and illumination
level of the interior lights (door position) according to whether the doors
are opened/closed and locked/unlocked.
The room light control system is controlled by the rear body control modul ...