NOTE:
If the following operations have been performed, initial setting is reset, and auto up/down operation are disabled. Therefore, performing initial setting is necessary.
Negative battery cable is disconnected..
Power window main switch connector is disconnected.
Power window system power supply fuse is removed.
1. Switch the ignition ON (engine off).
2. Press the driver's seat switch to fully open the door glass.
3. Pull up the driver's seat switch to the manual-up position to fully close the door glass and keep holding the switch up at the position for approx. 2 s
.
Power Window System
Power Window System Preliminary Inspection [Power Window System]Fuel Filter (High Pressure) Removal/Installation
WARNING:
Fuel is very flammable liquid. If fuel spills or leaks from the pressurized
fuel system, it will cause serious injury or death and facility breakage. Fuel
can also irritate skin and eyes. To prevent this, always complete the “Fuel
Line Safety Procedure”, while referring ...
Personalization Features
The following systems can be customized.
When performing a customized setting, refer to the referenced section for
the detailed setting procedure.
Security And Locks
NOTE:
There are two types of customization procedures; one using the M-MDS and
the other using the ...
Windshield Wiper Motor And Link Removal/Installation
1. Disconnect the negative battery cable..
2. Remove the following parts:
a. Windshield wiper arm and blade.
b. Cowl grille.
CAUTION:
Always affix protective tape to the windshield end. If the windshield wiper
motor and link contacts the windshield, it could damage the windshield. ...