IAT Sensor No.1

Resistance inspection

NOTE:

1. Disconnect the negative battery cable..

2. Disconnect the MAF sensor/IAT sensor No.1 connector.

3. Measure the resistance between MAF sensor/IAT sensor No.1 terminals A and B.


Specification


IAT (°C {°F})

Resistance (Kilohms)

?20 {?4}

13.7—16.6

20 {68}

2.49—2.79

60 {140}

0.622—0.703



IAT Sensor No.2

Resistance inspection

NOTE:

1. Disconnect the negative battery cable..

2. Disconnect the MAP sensor/IAT sensor No.2 connector.

3. Remove the MAP sensor/IAT sensor No.2..

4. Measure the resistance between MAP sensor/IAT sensor No.2 terminals A and B.


Specification


IAT (°C {°F})

Resistance (Kilohms)

0 {32}

Approx. 5.9

20 {68}

2.375—2.625

80 {176}

Approx. 0.323

130 {266}

Approx. 0.0893



Intake Air System
Purpose, Outline A vacuum pump has been adopted which supplies stable vacuum to the power brake unit. Structural View System Diagram Vacuum Hose Routing Diagram Structur ...

Intake Air Temperature (Iat) Sensor
IAT Sensor No.1 Purpose/Function Detects the IAT before it passes through the throttle body as basic information for mainly determining the fuel injection amount. Detects the IAT be ...

Other materials:

Refrigerant Line
Purpose The system piping connects each related part of the refrigerant system. Construction Block-type piping has been adopted to the pipe connection, improving the efficiency of piping related servicing. The pipes in the piping system consist of the following parts. ...

Auto Leveling Sensor Inspection
1. Disconnect the negative battery cable.. 2. Remove the auto leveling sensor.. 3. Prepare three dry cell batteries (1.5 V). 4. Connect the three dry cell batteries in a series. 5. Connect the positive pole of the dry cell battery to auto leveling sensor terminal C, and the negative po ...

Main Fuse
Purpose If electric current of the specified value or more flows to each fuse, the fuse melts due to heat generation to protect the systems and parts downstream of the fuse. Function If electric current to each fuse is the specified value or more, the fuse melts due to h ...

© 2016-2025 Copyright www.mcx5.org