1. Connect battery positive voltage to air intake actuator terminal B (or C), connect terminal C (or B) to ground, and then verify that the air intake actuator operates as shown in the table.



Terminal

Air intake actuator operation

B

C

B+

Ground

FRESH > RECIRCULATE

Ground

B+

RECIRCULATE > FRESH


Air Intake Actuator Inspection [Full Auto Air Conditioner]
1. Connect battery positive voltage to air intake actuator terminal B (or C), connect terminal C (or B) to ground, and then verify that the air intake actuator operates as shown in the table. ...

Air Intake Actuator Removal/Installation [Full Auto Air Conditioner]
1. Disconnect the negative battery cable.. 2. Remove the glove compartment.. 3. Disconnect the air intake actuator connector. 4. Remove the screw, then remove the air intake actuator. 5. I ...

Other materials:

Hydraulic Pressure Control System Outline [Fw6 A EL, Fw6 Ax EL]
Outline The hydraulic control mechanism consists of an oil cooler which maintains the hydraulic pressure at the optimum temperature, a control valve body and each shift valve which perform adjustment and circuit switching of the hydraulic pressure based on the control content calcula ...

Air Bag Module And Pre Tensioner Seat Belt Deployment Procedures [Two Step Deployment Control System]
WARNING: A live (undeployed) air bag module, pre-tensioner seat belt or lap pre-tensioner seat belt may accidentally operate (deploy) when it is disposed of and cause serious injury. Do not dispose of a live (undeployed) air bag module, pre-tensioner seat belt or lap pre-tensioner s ...

Engine Coolant Temperature (ECT) Sensor Inspection
Resistance Inspection WARNING: When the engine is hot, it can badly burn. Turn off the engine and wait until it is cool before removing the ECT sensor. ECT Sensor No.1 1. Remove the ECT sensor No.1.. 2. Place the ECT sensor No.1 in water with a thermometer, and heat the water ...

© 2016-2025 Copyright www.mcx5.org