Purpose/Function
The down switch detects the shift down operation of the selector lever.
The down switch signal is sent to the TCM via CAN and is used for manual shift control and engine-transaxle integration control.
Construction
The down switch is installed to the selector lever.
The down switch is an on/off type switch.

Operation
When the selector lever is in the shift down position (-), the down switch contact point closes.
Based on the opening and closing of the down switch contact point, the TCM detects that the shift down has been operated.

Down Switch Inspection [Fw6 A EL, Fw6 Ax EL]
Drive Plate Removal/Installation [Fw6 A EL, Fw6 Ax EL]Air Intake Actuator [Manual Air Conditioner]
Purpose
The air intake actuator moves the air intake door in the blower unit to switch
the air intake port.
Function
The air intake actuator drives the motor based on the signal from the climate
control unit and moves the air intake door to the FRESH or REC position.
...
Pressure Control Valve Inspection [Skyactiv G 2.0]
1. Remove the pressure control valve assembly..
CAUTION:
Do not apply a pressure 36 kPa {0.37 kgf/cm2, 5.2 psi} or more. Doing so
will damage the pressure control valve and evaporative hose.
2. Apply a pressure of 36 kPa {0.37 kgf/cm2, 5.2 psi} to port A.
3. Verify that ther ...
Evaporative Emission (Evap) Control System
Purpose, Outline
Prevents release of evaporative gas into the atmosphere.
The intake manifold vacuum introduces evaporative gas to the intake manifold
via the charcoal canister and the purge solenoid valve.
System Diagram
U.S.A. and CANADA
Except U.S.A. and CANADA
...