1. Measure the clearance around the entire circumference between the pressure plate and A/C compressor pulley using a thickness gauge.

2. Verify the clearance.
If not within the specification, remove the pressure plate and adjust the clearance by changing the shim (0.2 mm {0.008 in}, 0.5 mm {0.02 in}
) or the number of shims.
0.35—0.65 mm {0.014—0.025 in}

Magnetic Clutch Adjustment [Full Auto Air Conditioner]
Magnetic Clutch Disassembly/Assembly [Full Auto Air Conditioner]Lubrication System
Outline
Pressure loss is reduced by optimizing the oil passage.
With the adoption of the chain drive type oil pump, oil pump drive force
has been reduced.
With the adoption of the oil shower pipe, sliding resistance has been reduced.
With the adoption of the engine ...
Canister Vent (Cv) Solenoid Valve
U.S.A. And CANADA
Purpose, function
Seals the atmosphere side of the charcoal canister during EVAP leak check
monitoring.
Construction
Included in the charcoal canister.
The CV solenoid valve is consists of O-rings.
Operation
According to the ...
Check Valve
Except U.S.A. And CANADA
Purpose, function
The check valve maintain the pressure in the fuel tank at constant pressure.
Construction
The check valve is installed to the side of the charcoal canister.
Mainly consists of valve, umbrella, and spring.
O ...