NOTE:
If the following operations have been performed, initial setting is reset, and auto up/down operation are disabled. Therefore, performing initial setting is necessary.
Negative battery cable is disconnected..
Power window main switch connector is disconnected.
Power window system power supply fuse is removed.
1. Switch the ignition ON (engine off).
2. Press the driver's seat switch to fully open the door glass.
3. Pull up the driver's seat switch to the manual-up position to fully close the door glass and keep holding the switch up at the position for approx. 2 s
.
Power Window System
Power Window System Preliminary Inspection [Power Window System]Security Indicator Light
Purpose
Notifies the driver that the immobilizer system is operating.
Function
If a malfunction is detected in the immobilizer system, the DTC can be verified
by the flashing pattern of the security indicator light.
Construction
The security indicator light is bui ...
Positive Crankcase Ventilation (PCV) Valve Inspection
Airflow Inspection
1. Disconnect the section (A) of ventilation hose shown in the figure.
2. Start the engine and verify that vacuum is applied to the end of the disconnected
ventilation hose while the engine is idling.
If vacuum is not applied to the ventilation hose, perform the p ...
Vacuum Pump [Skyactiv G 2.0]
Purpose, Function
Ensures vacuum required for braking force to compensate for the decrease
in intake manifold vacuum applied to the power brake unit caused by the retard
intake valve closing.
Construction
The vacuum pump is installed to the rear housing.
For s ...