NOTE:
If the following operations have been performed, initial setting is reset, and auto up/down operation are disabled. Therefore, performing initial setting is necessary.
Negative battery cable is disconnected..
Power window main switch connector is disconnected.
Power window system power supply fuse is removed.
1. Switch the ignition ON (engine off).
2. Press the driver's seat switch to fully open the door glass.
3. Pull up the driver's seat switch to the manual-up position to fully close the door glass and keep holding the switch up at the position for approx. 2 s
.
Power Window System
Power Window System Preliminary Inspection [Power Window System]Check Valve Removal/Installation
Except U.S.A. And CANADA
1. Remove the floor under cover..
2. Remove in the order indicated in the table.
1
Evaporative hose
2
Check valve
3. Install in the reverse order of removal. ...
Solar Radiation Sensor Inspection [Full Auto Air Conditioner]
1. Shine a fluorescent light or expose the solar radiation sensor to natural
sunlight.
2. Connect the positive (+) lead to terminals B, C and negative (-) lead to terminal
A of the solar radiation sensor, and verify that the voltage value is output.
If the voltage is 0 V, replace ...
Relay And Fuse Block
Purpose
Relays and fuses used by each system are grouped and housed together for
smooth inspection and replacement servicing.
Function
Relays and fuses used by each system are grouped and housed together.
Construction
Installed in the engine compartment.
...