Chevrolet Spark manuals

Mazda CX-5 Service & Repair Manual: Water Pump Removal/Installation

Mazda CX-5 Service & Repair Manual / Engine / Cooling / Water Pump Removal/Installation

WARNING:

NOTE:

1. Disconnect the negative battery cable..

2. Remove the front under cover No.2..

3. Remove the splash shield (RH)..

4. Drain the engine coolant..

5. Remove the water pump drive belt with the generator drive belt still installed and set it out of the way..

6. Remove in the order indicated in the table.

7. Install in the reverse order of removal.

8. Refill the engine coolant..

9. Inspect for engine coolant leakage..



1

Water pump pulley

(See Water Pump Pulley Removal Note.)

(See Water Pump Pulley Installation Note.)

2

Water pump component

(See Water Pump Component Removal Note.)

(See Water Pump Component Installation Note.)

3

Gasket

4

O-ring

(See O-ring Installation Note.)


Water Pump Pulley Removal Note

CAUTION:

1. Align the water pump pulley hole with the water pump hole as shown in the figure.


2. Insert an appropriate bolt (length 70 mm {2.8 in}) into the water pump hole shown in the figure and lock the water pump pulley against rotation.


3. Remove the bolt used for locking the water pump pulley against rotation.

Water Pump Component Removal Note

1. Remove the water inlet pipe stay bolt.


2. Place a container under the engine to collect the engine coolant remaining in the engine.

3. Slightly loosen the three water pump component bolts shown in the figure and collect the draining engine coolant into a container.


CAUTION:

4. After the engine coolant stops draining, remove the water pump component.

O-ring Installation Note

CAUTION:

1. Apply engine coolant to a new O-ring.

2. Install the O-ring to the water inlet pipe.

Water Pump Component Installation Note

CAUTION:

1. Insert a new water pump gasket into the water pump groove.

2. Install the water pump.

3. Tighten the bolts in the order shown in the figure.


    Tightening torque

  1. 20—26 N·m {2.1—2.6 kgf·m, 15—19 ft·lbf}

4. Clean away the sealant adhering to the bolt hole on the cylinder block side of the water inlet pipe stay.

5. Remove the engine oil solenoid valve to secure a sufficient space for installing the water inlet pipe stay bolt..

6. Install a new water inlet pipe stay bolt.


7. Install the engine oil solenoid valve..

Water Pump Pulley Installation Note

CAUTION:

1. Install the water pump pulley to the water pump and temporarily tighten the bolt

2. Align the water pump pulley hole with the water pump hole as shown in the figure.


3. Insert an appropriate bolt (length 70 mm {2.8 in}) into the water pump hole shown in the figure and lock the water pump pulley against rotation.


4. Completely tighten the water pump pulley bolt to the specified torque.

    Tightening torque

  1. 8—11 N·m {82—112 kgf·cm, 71—97 in·lbf}

5. Remove the bolt used for locking the water pump pulley against rotation.

Shroud Upper Reinforcement Removal [Panel Replacement]
Symbol Mark Removal Procedure 1. Drill the 4 locations shown in the figure. NOTE: When drilling the 4 locations shown in the figure, do not drill a hole all the way through or there ...

Water Pump
Purpose, Function The water pump operates by obtaining drive force from the engine via the drive belt to pump engine coolant. Construction The water pump is installed to the eng ...

Other materials:

Liftgate Opener Switch Inspection
1. Disconnect the negative battery cable.. 2. Remove the following parts: a. Liftgate upper trim. b. Liftgate side trim. c. Liftgate lower trim. d. Liftgate garnish. e. Liftgate opener switch. 3. Verify the continuity of liftgate opener switch terminals B and C. If not as i ...

Headlight Aiming
NOTE: Perform headlight aiming if any of the following work is performed. Front combination light replacement Work that can affect vehicle height such as suspension replacement or removal/installation. 1. Empty the vehicle by having all occupants leav ...

Push Button Start Inspection
1. Remove the push button start.. 2. Verify that the continuity between the push button start terminals is as indicated in the table. If the continuity can be verified as indicated in the table, go to the next step. If not as indicated in the table, replace the push bu ...