Purpose, Function
The starter interlock switch mechanism prevents vehicle surge when the engine is started, enhancing safety. The engine cannot be started unless the clutch is depressed.
Construction
The mechanism is provided with a starter interlock switch on the circuit under the START STOP UNIT and thePCM.

Operation
Depressing the clutch pedal presses the starter interlock switch rod. At this time, the starter interlock switch is on, and the power circuit to starter closes. Accordingly, the starter operates only when the clutch is depressed and the engine can be started.

Fail-safe
Function not equipped.
Starter Interlock Switch Removal/Installation [C66 M R]
Synchronizer Mechanism [C66 M R]Tire Pressure Monitoring System Set Switch
Purpose
The tire pressure monitoring system set switch is used to initialize the
tire pressure monitoring system.
Construction, Operation
The tire pressure monitoring system set switch is installed to the instrument
panel.
The tire pressure monitoring sy ...
Airflow Temperature Control [Full Auto Air Conditioner]
Purpose
The airflow temperature control changes the airflow temperature according
to the vehicle conditions.
Function
The air mix actuator is driven and the air mix door position is changed according
to the set temperature and the vehicle environment.
The climate co ...
Evaporator Temperature Sensor Inspection [Full Auto Air Conditioner]
NOTE:
Inspect the evaporator temperature sensor when it is installed to the A/C
unit.
1. Set the fan speed at MAX HI.
2. Set the temperature control at MAX COLD.
3. Set the RECIRCULATE mode.
4. Turn the A/C switch off.
5. Close all doors and windows.
6. Wait for 5 min.
7 ...