NOTE:
Measure the refrigerant pressure after approx.10 min
have elapsed from engine start.
1. Install the manifold gauge..
2. Start the engine and warm it up.
3. Set the fan speed MAX HI.
4. Turn the A/C switch on.
5. Set to RECIRCULATE mode.
6. Set the temperature control to MAX COLD.
7. Set to VENT mode.
8. Close all the doors and all the windows.
9. Maintain the engine speed at 1,500 rpm
.
10. Measure the ambient temperature and high- and low- pressure side reading of the manifold gauge.
11. Verify that the intersection of the pressure reading of the manifold gauge and ambient temperature is in the shaded zone.

If there is any malfunction, inspect the refrigerant system according to the troubleshooting chart.
Refrigerant Line Removal/Installation
Refrigerant Pressure Sensor Inspection [Full Auto Air Conditioner]Fuel Injector
Purpose, Function
Promotes atomization of fuel by injecting it from the multiple holes.
Injects fuel according to the control signal from the PCM.
Construction
The fuel injector is installed to the cylinder head.
The fuel injector has multiple injection hole ...
Cooling Fan Relay [Skyactiv G 2.0]
Purpose, Function
The cooling fan relay operates by receiving the signal from the PCM to supply
power to the cooling fan motor.
Construction
The cooling fan relay is installed on the relay and fuse block.
Operation
The contact point is on when the battery vo ...
Climate Control Unit Inspection [Manual Air Conditioner]
1. Remove the climate control unit with the connector connected..
2. Switch the ignition ON (engine off or on).
3. Connect the negative (-) lead of the tester to the body ground.
4. By inserting the positive (+) lead of the tester into the climate control
unit connector, measure the voltage ...