NOTE:
Measure the refrigerant pressure after approx.10 min
have elapsed from engine start.
1. Install the manifold gauge..
2. Start the engine and warm it up.
3. Set the fan speed MAX HI.
4. Turn the A/C switch on.
5. Set to RECIRCULATE mode.
6. Set the temperature control to MAX COLD.
7. Set to VENT mode.
8. Close all the doors and all the windows.
9. Maintain the engine speed at 1,500 rpm
.
10. Measure the ambient temperature and high- and low- pressure side reading of the manifold gauge.
11. Verify that the intersection of the pressure reading of the manifold gauge and ambient temperature is in the shaded zone.

If there is any malfunction, inspect the refrigerant system according to the troubleshooting chart.
Refrigerant Line Removal/Installation
Refrigerant Pressure Sensor Inspection [Full Auto Air Conditioner]Corner Junction Installation [Panel Replacement]
Symbol Mark
Installation Procedure
1. When installing new parts, measure and adjust the body as necessary to conform
with standard dimensions.
2. Drill holes for the plug welding before installing the new parts.
3. After temporarily installing new parts, make sure the related parts fit p ...
Thermostat Inspection
1. Remove the thermostat..
2. Visually check that the thermostat valve is closed.
3. Place the thermostat in water.
WARNING:
During inspection, the thermostat and water are extremely hot and can cause
severe burns. Do not touch the thermostat and water.
4. Heat the water and c ...
Up Switch [Fw6 A EL, Fw6 Ax EL]
Purpose/Function
The up switch detects the shift up operation of the selector lever.
The up switch signal is sent to the TCM via CAN and is used for manual shift
control and engine-transaxle integration control.
Construction
The up switch is installed to the selector l ...