1. Inspect the condenser for cracks, damage, and oil leakage.
If there is any malfunction, replace the condenser.
2. Visually inspect for bent fins for clogging of foreign material.
If any fins are clogged, remove the foreign material.
3. Visually inspect for bent fins.
If any fins are bent, use the end of a flathead screwdriver to straighten fins.
Condenser
Condenser Removal/InstallationFilament Inspection
1. Switch the ignition ON (engine off).
2. Turn the rear window defroster switch on.
CAUTION:
Directly touching the rear window defroster filament with the lead of the
tester could damage it. Wrap aluminum foil around the end of the lead and inspect
the filament by touching it ...
Starter [Skyactiv G 2.0]
Purpose, Function
The starter rotates the crankshaft via the ring gear and it serves as a trigger
to start the engine.
Construction
The starter is installed to the rear part of the engine on the left side.
The starter is a coaxial reduction type which can obt ...
Tie Rod Inspection
1. Inspect for bending and damage.
If there is any malfunction, replace the tie rod.
2. Inspect for excessive play.
If there is any malfunction, replace the tie rod.
3. Swing the tie rod five times.
4. Measure the swing torque of the tie rod using a pull scale.
...