1. Inspect the condenser for cracks, damage, and oil leakage.
If there is any malfunction, replace the condenser.
2. Visually inspect for bent fins for clogging of foreign material.
If any fins are clogged, remove the foreign material.
3. Visually inspect for bent fins.
If any fins are bent, use the end of a flathead screwdriver to straighten fins.
Condenser
Condenser Removal/InstallationReduction Gear
Purpose/ Function
The reduction gear transmits the rotation input from the EPS motor, decreasing
the rotation speed and increasing the torque simultaneously.
Construction
The reduction gear consists of the worm wheel located on the steering column
main shaft and the worm sh ...
Cooling Fan Relay
Purpose, Function
The cooling fan relay operates by receiving the signal from the PCM to supply
power to the cooling fan motor.
Construction
The cooling fan relay is installed on the relay and fuse block.
Operation
The contact point is on when the battery vo ...
Relay Inspection
Relay Type
Connector type
Part name
Type A
TNS relay
A/C relay
Headlight HI relay
Headlight LO relay
Headlight LO relay (LH)
Horn relay
ACC rel ...